GenSet Model | GDC 120 *S |
Continuous Output | 96 KW / 120 KVA |
Engine Brand & Model | Cummins 6BTA5.9G2 |
Type | Water-cooled, 4-stroke, Natural Engine |
No. of cylinder | 6 |
Bore x Stroke | 1 02 x 120 mm |
Engine power | 106 kw |
Compression ratio | 17. 3 : 1 |
Fuel consumption | ≤ 27L/h |
Displacement | 5 .9L |
Engine speed | 1500rpm |
Lubricant Capacity | 14.2 L |
Starting system | D. C. 24V electric start |
Cooling way | Positive Water Cooling Cycle |
Alternator Brand & Model | GODLIKE JDG274 DS (prime power 120 kva) |
Frequency | 50HZ |
Voltage | 380/220V |
No. of phases | 3 |
Excitation | brushless |
Insulation class | H |
Power factor | 0.8 |
Protection Grade | IP23 |
Noise control | ≤75db in 7 metres |
Voltage Regulation, Steady State | ≤ ± 1% |
Control Panel - Standard equipped or LCD digital control module(DSE&SMARTGEN) | |
8hours Base Fuel Tank & battery included | |
Options: ATS |
Optional Accessories
1. ATS(Automatic Transfer Switch);
Which can start the diesel generator when the main power is off; when the main power comes back, it will shut down generator.
2. MCCB (Molded case circuit breaker);
It can protect the loading machine and the diesel generator.
3. Battery charger(float charger);
When the generator hasn't been used for long time, the batteries will be no power, in that way, you can't start the generator. But the battery charger can charge the batteries from main power.
4. Extra daily fuel tank;
It will be requested while the base fuel tank capacity is not enough for daily fuel consumption.
5. Paralleling system;
This system can make several generators work together and automatically distrubute the load according to set.
6. Remote Control Panel:
Which can control the generator by computer, if use a RS484 or RS232 digital cable to connect the generator to the computer
7. Water Separate(additional cooling system);
Item
No |
Genset Model
Open Type |
Power Out Put
400V/50HZ/1500RPM/3P/0.8(Y) |
Doosan
Engine Model |
GODLIKE
Alternator Model |
Control Modle | |||
Prime Power | Standby Power | |||||||
1 | GDD50 | 50KW | 63KVA | 55.0kW | 68.8kVA | DB58/54KW | JDG224E/48KW | HGM Smartgen 6110K |
2 | GDD64 | 64KW | 80KVA | 70.0kW | 87.5kVA | D1146/77KW | JDG224GS/64KW | HGM Smartgen 6110K |
3 | GDD96 | 96KW | 120KVA | 101.0kW | 126.3kVA | D1146T/108KW | JDG274DS/96KW | HGM Smartgen 6110K |
4 | GDD100 | 100KW | 125KVA | 110.0kW | 137.5kVA | D1146T/108KW | JDG274D/100KW | HGM Smartgen 6110K |
5 | GDD140 | 140KW | 175KVA | 145.0kW | 181.3kVA | P086TI-1/149KW | JDG274G/152KW | HGM Smartgen 6110K |
6 | GDD160 | 160KW | 200KVA | 176.0kW | 220.0kVA | P086TI/177KW | JDG274H/160KW | HGM Smartgen 6110K |
7 | GDD220 | 220KW | 275KVA | 242.0kW | 302.5kVA | P126TI/241KW | JDG314DS/220KW | HGM Smartgen 6110K |
8 | GDD240 | 240KW | 300KVA | 264.0kW | 330.0kVA | P126TI-II/265KW | JDG314D/240KW | HGM Smartgen 6110K |
9 | GDD300 | 300KW | 375KVA | 330.0kW | 412.5kVA | P158LE-1/327KW | JDG314FS/304KW | HGM Smartgen 6110K |
10 | GDD320 | 320KW | 400KVA | 370.0kW | 462.5kVA | P158LE/363KW | JDG314F/320KW | HGM Smartgen 6110K |
11 | GDD368 | 368KW | 460KVA | 407.0kW | 508.8kVA | DP158LC/408KW | JDG354C/360KW | HGM Smartgen 6110K |
12 | GDD420 | 420KW | 525KVA | 464.0kW | 580.0kVA | DP158LD/464KW | JDG354ES/450KW | HGM Smartgen 6110K |
13 | GDD456 | 456KW | 570KVA | 503.0kW | 628.8kVA | DP180LA/502KW | JDG354ES/450KW | HGM Smartgen 6110K |
14 | GDD507 | 507KW | 634KVA | 559.0kW | 698.8kVA | DP180LB/556KW | JDG354FS/500KW | HGM Smartgen 6110K |
15 | GDD552 | 552KW | 690KVA | 608.0kW | 760.0kVA | DP222LB/604KW | JDG354G/560KW | HGM Smartgen 6110K |
16 | GDD601 | 601KW | 751KVA | 664.0kW | 830.0kVA | DP222LC/657KW | JDG404B/600KW | HGM Smartgen 6110K |